PERMANENT STOCK

PERMANENT STOCK

Regulator Kit + Butane Rubber And Clamps 30Gr Domestic Approved
✅ Complete kit for butane and propane gas installations.Gas regulator. Pressure 30 grs. 2 Stages. Butane rubber hose and two clamps.✅ Approved hose with a length of 1, 5 m + domestic butane regulator suitable for connecting to appliances operating with an inlet pressure of 30 mbar. Inner diameter of the hose: 9 x 15 mm; manufacturing and expiry date marked on the hose. The hose must not be used after its expiry date.✅ Guaranteed flow rate: 2.5 kg/h, supply pressure: 0, 6-16 bar and shut-off pressure: 63 mbar.✅ Inlet connection: g-56 (une-en 12864); outlet connection: h-51 (une-en 12864).✅ Regulator or gas cylinder regulator head. Check the type of regulator and the working pressure of your appliance before placing your order. Suitable for cookers, gas heaters, boilers, catalytic heaters, barbecues, paella burners, water heaters…
3 Bottles Gas Minus 60 350Gr Substitute R32, R410A Freeze Organic
✅ 100% organic refrigerant gas Minus 60 For systems with R410A, R32 and substitutes. Disposable container 995ml. Net weight 350g. See pressure tables for adjustment and the safety data sheet, HYCHILL.✅ Minus 60 is a high-purity blend of propane R290 and ethane R170, an ideal alternative to synthetic refrigerants [R410A and R32]. HyChill Minus 60 is the natural solution for converting air conditioning systems previously charged with synthetic refrigerants..✅ Features: Minus 60 Excellent performance at high and extreme ambient temperatures Fast cooling effect Superior energy efficiency Operates at lower pressures than synthetic refrigerants.✅ Systems: switching from synthetic fluorocarbon refrigerants can drastically reduce energy bills and improve the service life of the RAC system. Can be used in an R410A and R32 compressor. compatible with R410A and R32 heat exchangers and expansion devices and common refrigeration materials and lubricants. Some AC systems may not be suitable for Minus 60 conversions (especially when pressure is used for system control).
3 Minus 60 Gas Bottles 350Gr + Valve + Hose Substitute R32, R410A Freeze Organic
✅ 100% organic refrigerant gas Minus 60 For systems with R410A, R32 and substitutes. Disposable container 995ml. Net weight 350g. See pressure tables for adjustment and the safety data sheet, HYCHILL.✅ Minus 60 is a high-purity blend of propane R290 and ethane R170, an ideal alternative to synthetic refrigerants [R410A and R32]. HyChill Minus 60 is the natural solution for converting air conditioning systems previously charged with synthetic refrigerants..✅ Features: Minus 60 Excellent performance at high and extreme ambient temperatures Fast cooling effect Superior energy efficiency Operates at lower pressures than synthetic refrigerants.✅ Systems: switching from synthetic fluorocarbon refrigerants can drastically reduce energy bills and improve the service life of the RAC system. Can be used in an R410A and R32 compressor. compatible with R410A and R32 heat exchangers and expansion devices and common refrigeration materials and lubricants. Some AC systems may not be suitable for Minus 60 conversions (especially when pressure is used for system control).
Vaillant 3 Bars Boiler Safety Valve
Safety Valve For All Boiler Models.
Suitable For Electric Heaters And Water Heaters.
Maximum Pressure: 3 Bars
Compatible With Vaillant Brand Models. List Of Compatibilities Indicated In The Product Description.
Compatible Models: (Vmi 282-7 R2, Vmw275/3-7H, Vmi280/7, 282/7, Vmw242-2-3R2, Vmi 280-7R3) C.O.190732
Standard Fryer Plug Aluminum Ceramic 220/380V 35A
✅ Secure connection: Provides a stable and secure connection between the fryer and the power outlet.✅ Durable material: Made of high-quality aluminium and ceramic to withstand high temperatures and ensure durability.✅ Standard compatibility: Standard design that fits a wide range of domestic and commercial fryers.✅ Electrical and thermal insulation: The ceramic used provides safe electrical and thermal insulation, even under high-temperature conditions.✅ Easy installation: Standard plug that makes installation and connection to the power outlet easy.✅ Durable construction: Aluminium ensures corrosion resistance and a long service life.
Flow Regulator Control Control Heater 5 Liters Cointra Cm 5
✅ Water flow control knob compatible with Cointra CM-5 water heaters, reference RE370270002.
✅ Regulation component used to manually adjust water flow into the heater, affecting service flow rate and outlet temperature.
✅ Designed to fit the Cointra CM-5 adjustment system, ensuring correct actuation of the regulator and stable control during operation.
✅ Replacement recommended when the knob becomes loose, stiff to turn, blocked, the fixing breaks, or flow can no longer be adjusted correctly.
Refrigerant Gas Recovery Filter Filter Recycling
Filter Viewer For Refrigerant Gas Recovery. By Adding This High±-Porosity Filter To Your Recovery Equipment You Can Recycle Refrigerant Gases. Trap Filter Effectively Traps Sealants, Colorants, Additives, And Lubricants So That Only Pure Coolant Reaches Your Recovery Equipment. The Maintenance Of The Filter Is Fast, In Less Than 5 Minutes, And Simple Thanks To Its Drainage System. Made In The Usa
Sonda Temperatura Compatible con Baxi Compatible con Roca Acs Caldera Unidad 122155310
✅ Boiler domestic hot water temperature sensor. 1 unit. Also called safety probe – temperature limiter – immersion sensor – submerged thermistor – NTC probe, green colour.✅ Male thread 9, 8 mm. Bulb diameter 6 mm. Bulb length 11, 5 mm. Hexagonal head for 13 mm wrench.✅ compatible with Baxi/compatible with Roca. VICTORIA 20/20F VICTORIA 20 / 20 F RS20/20 RS20-20 BOILER R-20/20F LIMA 4, 6O GN NR-15/20 SP GN NR-15/20 SP GP. C.O. 122155310.✅ Primary circuit NTC probe The thermistor is an NTC (negative temperature coefficient) probe, located on the body of the three-way valve. It is a variable resistor made of semiconductor material, with the following behaviour: “as the temperature it is exposed to changes, its resistance will vary inversely, and vice versa”. With this characteristic, the thermistor is the element that informs the control device (electronic board processor) which modulates the boiler.✅ Secondary circuit NTC probe Allows the modulation board to detect the temperature of the water contained in the storage tank. It is fixed to the outer wall of the tank and placed in an immersion sleeve.